|
 
The ART ™System
by Petro Vend Fuel Controls combines the latest electronic design with
rock-solid durability to create a truly modern, 24-hour unattended
fueling system. To you, the petroleum marketer, that equals
profitability by offering your customers more options – from nationwide
networks to your own proprietary cards – with the reliability of little
or no system downtime. Only Petro Vend, the leader in automated fuel
control, can bring you a system like this.
The FIT500 ™
Fuel Island Terminal
Your customers will enjoy the ease of use and modern
aesthetics of Petro Vend’s newest line of Fuel Island Terminals. The
FIT500 ™
sports an impressive 10.4" TFT active
matrix color display. It’s so vivid, your full-color graphics will leap
off the screen. Personalize your site by using your PC to create
and load your own customized graphic images onto a flash memory card
that plugs in to the FIT500™.
Change the images as often as you like.
Additional
features:
-
Stainless steel enclosure for years of
maintenance-free operation
-
Dual-head cardreader and high-speed graphic receipt
printer
-
Modular design for easy upgrades
-
Wireless communication capability
-
Integral control for mechanical dispensers
How Does The ART ™
System Work?
Your customers are greeted at the Fuel Island Terminal
with a message you program into the system. The driver inserts a mag-card,
enters a code, or waves a proximity card, and keys in required PIN data
(and/or any of 9 other prompts you select). When the system
authenticates the user’s data, the pump is activated and the vehicle can
be fueled. Network transaction data is sent to the appropriate network
for processing while proprietary transaction data is recorded in the
system for later retrieval.
The FSC3000 ™
Fuel Site Controller
At the heart of every ART ™
System is the FSC3000™
Fuel Site Controller. It’s kept
indoors (remotely) for greater security of your stored transaction data,
site data, driver data and vehicle data. The FSC3000™
also allows access to many
fueling networks. Programming is done right from your PC using ARTWare™
software (see page 3 for more details).
Additional features:
™communication
reduces installation costs
Controls up to 16 mechanical/electronic dispensers
per system
Connects with OPW and many other tank gauges
Integral TCP/IP connectivity
Network dial-outs interface with multiple bank,
commercial fleet and trucking card networks
Software upgrades to the Fuel Site Controller can be
downloaded remotely to eliminate costly site visits
Reduces the wait for authorization by accessing two
different networks simultaneously
Networks
The ART™System
is capable of accepting the widest selection of commercial fueling network cards – helping you to drive
more traffic to your site. It can accept commercial fueling cards, truck
fleet cards and major bank cards. Networks supported include:
Paymentech,T-Chek, TCH, FleetOne, EFS, NBS and Comdata. The ART ™System
is field-upgradeable so you can easily add network interfaces to meet any
needs.
Other Popular Features
Registered Bankcards
The registered bankcard feature permits 24-hour fueling
in areas where unattended public fueling is generally restricted.
Customers are allowed access to fuel anytime with a PIN the FSC3000™
assigns to their bankcard, such as Visa®, MasterCard ®, etc.; so like
your proprietary card holders, you know they’ve been authorized and
trained to use the system safely. If the site is attended during the
day, simply turn off the PIN requirement, allowing anyone to fuel with
their credit card.
Multi-Trucking
The multi-trucking
feature allows you to accept popular trucking network cards like Comchek,
T-Chek, EFS, Voyager and WEX. Any combination of networks can be
accessed from the same Fuel Site Controller.
Profit with a Proprietary Fueling Network
Set up your own proprietary fueling network. Issuing
customers your fueling cards saves you money by eliminating network
fees.
ARTWare ™
Configuration Utility
With Petro Vend’s new ARTWare™ configuration software,
you’ll be able to conveniently configure your entire site (or sites)
from your own Windows®-compatible PC – on-line or off-line.
Use ARTWare™ to maintain a global database of
configuration settings that are common to multiple sites and separate
site databases for unique parameters, such as site I.D. Changes to
global configuration settings are saved and automatically uploaded to
other sites.
Intuitive user interface eliminates programming commands
Allows
off-line or on-line configuration of the FSC3000™
Maintains a global database of configuration settings that are
common to multiple sites
Maintains separate site databases for unique
parameters, such as site I.D.
Automatically uploads any changes made to configuration settings
when a connection is made to the FSC3000™
Changes
to global configuration settings are saved and automatically
uploaded to other sites
Complete your system with Phoenix™, Phoenix™ Plus, and the new
Phoenix™ Premier fuel management software, featuring multi-tiered
pricing and tank gauge interface
Phoenix™ PC Software for Advanced
Management
Phoenix™, Phoenix™ Plus, and Phoenix™ Premier
are powerful fuel
management software packages for your Windows®-compatible
PC. The intuitive user interface lets you easily navigate between
site, account, card and transaction screens. Phoenix™features
back-up and restore, terminal emulation and on-demand transaction
polling. Phoenix™Plus is
a powerful data management and communications software package that
gives you total, centralized control over your fueling operations.
Phoenix™ Premier offers complete site reconciliation by incorporating
additional site data from your OPW tank gauge or other brand of tank
gauge (see the Phoenix™ Premier sales literature for details). Most data
can be exported to third-party database, spreadsheet and fleet
maintenance programs for further processing.
Phoenix™ includes a new Autopoll Scheduler that lets you
schedule activities to be automatically performed daily, weekly or
monthly. These activities include: capturing transaction data, backing
up site configurations and backing up or updating card records. There’s
also a built-in help feature to assist you with each option. You can
store address, phone number, tank, site employee and fuel provider
information for each site. Phoenix™ even lets you export your
transactions in Excel 5.0, HTML, dBASE IV, FoxPro 2.5, Lotus 1-2-3 WK3,
Paradox 4.x and two ASCII formats: CSV (comma separated variable width)
and SDF (space delimited fixed width). With Phoenix™ Plus, you get all
of the above–plus the following features:
Card
Management
This feature lets you make changes to your card database
in one central location for multiple sites. Fuel Island Terminals are
then automatically updated during routine polling.
Reporting
This feature consolidates data from multiple sites at
one time with the click of a button and schedules the printing of
reports and export data. This reporting capability also includes any
network transactions that are found in Fuel Site Controller software
versions like VisaNet and Multi-Trucking. Phoenix™ allows you to choose
from over 60 different types of reports. They include: Account,
Card 1 and Card 2 Master File Listing, Site Sales, Product Sales,
Account Sales, Transaction and Pump Total reports.
Enhanced
Odometer Checking
This feature lets you easily find obvious, incorrect
mileage entries such as single, sequential or repeated numbers.
You can define an average MPG with a tolerance for each card, which is
then used to verify the amount fueled against the odometer entry.
|
|
| Enclosure
Dimensions: |
17 3/4"W,
20"H, 11 3/8"D |
| Input Power: |
120/240
VAC 50/60 Hz, 250 Watts |
| Operating Temperature: |
-40° F to 122°F
(-40°
to 50°C) |
| Governing Standards: |
ETL |
|
FUEL SITE CONTROLLER
SPECIFICATIONS: |
| Enclosure
Dimensions: |
2" H x
10"
W x 11" D |
| Input Power: |
85 - 240 VAC 50/60 Hz,
25 Watts |
| Operating Temperature: |
32° F to 122° F (0° to
50° C) |
| Serial Communication
Ports: |
Petro-Net (RS-485),
Printer (RS-232), Terminal (RS-232), Modem (RS-232),
Pass-through (RS-232), 2 Auxiliary Ports (RS-232), Tank Gauge,
Ethernet |
|
Pump Control Module
Specifications: |
| Relay
Rating: |
1 HP,
120/240 VAC |
| Pulser Compatibility: |
Contact/ 12 VDC
Electronic |
| Pulser Power Supply: |
12 VDC; 40 milliamps
max./ pulser |
| Pulser Rate: |
1:1 to 9,999:1 (in one
pulse increments) |
| Pulser Speed: |
6,000 pulses/minute
(mechanical) 100,000
pulses/minute (electronic) |
| Pulser Type: |
Single channel |
Phoenix™ for Windows® and ARTWare™ Minimum PC
Requirements
A Pentium® processor, 32 MB RAM, CD-ROM drive, 100 MB
hard disk space, SVGA monitor, Windows 95, Windows 98, Windows 2000,
Windows NT®, Windows ME® or Windows XP® operating system and an
available communications port.
Because
every site & application is different please contact Phil or Brett for a
quote at
phil@strickequipment.com
or
brett@strickequipment.com
|