Your Connection to Move the World

 

SITE SENTINEL iTOUCH

"Distributors of
Petroleum Equipment"

Toll Free: 1-877-737-4690   Fax: 616-457-8919

HOME CONTACT INFO LOCATION TERMS TANK CLEANING SPECIALS




SITE SENTINEL iTOUCH

OPW's Site Sentinel® iTouch is a multifunction, high quality tank monitoring system that provides real time, accurate inventory information for up to 16 underground storage tanks.  The enhanced performance of the SiteSentinel® iTouch improves data processing, allows for future system expansion and can be customized to meet each user's needs.

Features

  • Provides real-time, accurate inventory information

  • Displays gross or net-corrected tank volume, product level, water level, ullage, and temperature for individual tanks.

  • Available output module provides multi-purpose relays, which can be used for outputs such as overfill or sensor alarms

  • Third Party Certified automatic or on-demand leak detection meets and/or exceeds U.S. Environmental Protection Agency regulatory requirements

Because of the many different options and every site is different every system will be quoted separately.
 Please contact Phil or Brett for more information and pricing at:
phil@strickequipment.com or brett@strickequipment.com 
 

CONSOLE SPECIFICATIONS:
Dimensions: 23.5 cm H x 31.1 cm W x 13.3 cm D (9.3"H x 12.3"W x 5.2"D)
Operating Temperature: -10°C to 50°C (14°F to 122°F)
Power Requirements: Input Power: 100-250 VAC, 50/60 Hz, 0.5 A
Input Contact: 12VDC, 40 mA max.
Output Contact: 30V AC/DC, 2A
Output Module Contact: 2A@ 120/240 AC, 2A@ 24VDC
Listings and Approvals: ETL
TLM SPECIFICATIONS:
Number of tanks: Up to 16 underground storage tanks
Probe Inputs: Intrinsically safe magnetostrictive
Level Precision: ± 0.0005" (0.0127 mm)
Level Accuracy: ± 0.04" (1mm)
Temperature: ± 0.001° F (± 0.0005° C)
0.2 GPH (0.76 lph) Static Leak Test: 98.18% Pd, 1.82% Pfa
0.1 GPH (0.381 lph) Static Leak Test: 96.5% Pd, 3.5% Pfa
0.2 gph (0.76lph) Continuous Leak Test 99.1% Pd, 0.9% Pfa
EPA Leak Test Certified:

15,000 gallon tank (56,781 liters)
35,000-gallon tank with SLD (132,475 liters) for single or manifold tanks

PROBE SPECIFICATIONS:
Type: Magnetostrictive/Float
Material: Stainless steel body, Aluminum cap
Location: Hazardous, Class I, Division 1, Group D
Temperature: 5 RTDs
Temperature Range: -40° F to 140° F (-40° C to 60°C)
Data Cable: 1000' (300m) Belden 88760 500' (150m) max. Belden 88761
LEAK SENSOR SPECIFICATION:
Number of Sensors: Up to 16
Sensor Types: IntelliSense
Discriminating Dispenser Pan: 30-0232-DH-10
Discriminating STP Sump: 30-0232-DH-20
Discriminating Interstitial: 30-0236-LW
Discriminating Monitoring Well:

30-0234-HW-06 (6')
30-024-MW-15 (15')
30-0234-HW-20 (20')

Sump Sensor, Float Switch : 30-0231-L
Liquid Only Interstitial: 30-0230-S
Hydrocarbon Vapor Sensor: 30-0235-V
Interstitial Hydrocarbon
Liquid w/ Water Indicator
30-0234-HW-OL

 

Because of the many different options and every site is different every system will be quoted separately.
 Please contact us for a quote.